Web Analytics Made Easy - StatCounter

Brushless Alternator Tenders

Get complete information related to latest Brushless Alternator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Brushless Alternator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Brushless Alternator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :40330325 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For corrigendum : supply of ems repair at bsnl oa nadiad - attending fault ea set , attending fauls of ei , laycableupto 35 sq mm , sfixing 5 to 32a spn mcb , sfixing 20a tp mcb , sfixing 63a tpn mcb , sfixing bradided fuel pipe for ea , major overhauling 50 kva ea set , sfixing hosepipe st for50kva ea , rewindingfixing 2hp sub pumpset , sf 10 to 16a relay for pump panel , sf 10 to 16a sp mcb for pump panel , sf push button with element for pump , sf 400 mm wall fan , slaying 3c 2.5sq.mm cu cable as reqd , sf led indi lamps 220 v ac

Central Government And Public Sector

CTN :40477607 Due date: 16 Jul, 202516 Jul, 2025 1.14 Lacs
Tender For corrigendum : supply of ea set repair at wtr panwadi te bhavnagar - attending fault easet , bcheckservice of dg set 100 to 160 kva , calibration of fuel pump and nozzle 110kva ea , replacement electronic avr 110 to 250 kva ea , sf 10amp 24v smps battery charger , repair of 12 to 24v starter 100 to 250 kva , sf 12v 110ah mf battery , replace faulty part in ea set v belt , replace faulty part in ea set steel braided fuel pipe , replace faulty part in ea set lub pressure pipe , replace faulty part in ea set starter with with key , replace faulty part in ea set ac ammeter , replace faulty part in ea set pla relay , replace faulty part in ea set brass battery terminal , replace faulty part in ea set 16a hrc fuse , replace faulty part in ea set water hose pipe set , replace faulty part in ea set stop solenoid , replace faulty part in ea set minor joint gasket set , replace faulty part in ea set major joint gasket set , replace faulty part in ea set temp guage , replace faulty part in ea set frequency meter , control panel wiring by authorised service technician , service of engine radiator with chemical wash , repair water pump with service at authorised workshop

Central Government And Public Sector

CTN :40477848 Due date: 16 Jul, 202516 Jul, 2025 2.20 Lacs
Tender For corrigendum : supply of ems service te railwaypura - pvdg reneted oump for use , replace 50mm gi b class pipe , sf 3inch half turn valve gi , sf 2inch half turn valve gi , modify 3inch water line by pvdg 3inch flange , modify 3inch water line by pvdg 3inch nipple , modify 3inch water line by pvdg 3 inch tee , modify 3inch water line by pvdg 2.5 inch nipple , modify 3inch water line by pvdg 3 and 2.5 inch socket , modify 3inch water line by pvdg 2.5inch coupler , modify 3inch water line by pvdg 2 inch nipple , modify 3inch water line by pvdg 2 inch tee , sf 50 mm nrv , plumbing work for priming assembly , arrangement of automationof extg water supply by pvdg 5 hp dol starter , arrangement of automationof extg water supply by pvdg 63a 4p changeover mcb , arrangement of automationof extg water supply by pvdg auto timer 24 hrs , arrangement of automationof extg water supply by pvdg wlc , arrangement of automationof extg water supply by pvdg 63a 4p mcb , arrangement of automationof extg water supply by pvdg 3.5c 50 sq mm et , arrangement of automationof extg water supply by pvdg 200 a terminal , sitc 10kvar app capacitor , rewind ex fan ped fan motor upto 200w , rewind ceiling fan motor upto 1400 mm , replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , replace 2 module electronic regulator , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , conduct fire drill for bldg g plus 3 flr , service 11kv substation with ht panels , repair of substation panel by repacing led ind lamps 220v , repair of substation panel by repacing 2 to 4 a hrc fuse , repair of substation panel by repacing lml1 contactor kit , repair of substation panel by repacing bimettalic ol for blower mn2 , repair of substation panel by repacing spp ol relay mpr1 , repair of substation panel by repacing 8 pin 220v pla relay , repair of substation panel by repacing 0 to 400a ammeter ac , repair of substation panel by repacing 0 to 30 a ammeter ac , repair of substation panel by repacing 0 to 500v voltmeter ac , repair of substation panel by repacing dc ammeter 96mm , repair of substation panel by repacingdc voltmeter 96mm , repair of substation panel by repacing selector switch , b check service of dg set 320 kva , supply smps battery charger 24v 10a , sf 12v 130ah mf battery for ea set , supply brass battery terminals , pvdg led ind lamps 220v ea set , sfixing bradided fuel pipe for ea

Central Government And Public Sector

CTN :40140601 Due date: 16 Jul, 202516 Jul, 2025 5.53 Lacs
Tender For corrigendum : supply of call base ems repair at bsnl oa himatnagar - attending fault at te below 25 km , attending fault at te 25 to 50 km , attending fault at te more than 50 km , sf 12v 88ah battery , sf 12v 130ah battery , sf 10amp 12v smps battery charger , repair smps battery charger , service of dg set 40 to 62.5kva , service of dg set 100 to 125kva , service of dg set 320 kva , 320 kvadg set starter repair , calibration of fuel pump and nozzle , service radiator for ea set upto 125 kva , service radiator for ea set upto 160 to 320 kva , rewinding 3 to 5 hp mono water pump , dol starter for 5 hp motor , repalce sreet light with 25 watts led lamp in holder , repalce sreet light with 25 watts led lamp on pole , repalce pvc box , sf 4 ft 20 w white led tl , sf 3 c 2.5 sq mm cu cond cable , sf 3 c 1.5 sq mm cu cond cable , laying xlpe cable upto 35 sq mm , end termination for 4c 10 sq mm cable , dismental ac unit incl all , shifting of 1.5 tr sac unit incl all , itc of 1.5 or 2 tr split ac units , charging r 32 or r410 gas for sac , charging r 407 gas for sac , sf add copper pipe with cable for sac , sf25 mm pvc isi drain pipe , disemntaling all ems , servicing mv and lt panels incl all , repalce 400 a mccb incl shift and itc

Central Government And Public Sector

CTN :40702670 Due date: 16 Jul, 202516 Jul, 2025 5.14 Lacs
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair

CTN :40978246 Due date: 28 Jul, 202528 Jul, 2025 NA
Tender For supply of consumables for laboratory : - bottom connector for ea 18x2x1 mm , valco bulkhead connector , bush ceramic id 2.1 lg 3 , capillary fused silica 0.18_0.27 , ceramics column , spacer ring , spacer 24.8 x 21 x 1 ceramic , spacer 24 8 x 21 x 2 quartz , spacer 24.8 x 21 x 4 quartz , spacer tube od5x3.2x1.5l , capillary.fused silica id 0.32 , gasket fibre 8 x 5 , slit-0.2 source tantal , compressed air service unit , measurement needle gas bench , membrane complete , microspatula , nafion tubing f. gas dryer , pressure spring , connector m5 for tube , seal type 292.3406 , set dichtungsringe

Central Government / Public Sector

CTN :40995947 Due date: 10 Jul, 202510 Jul, 2025 NA
Tender For supply of nylon 66 bush for suspension of 4.5 kw, 110 v dc brushless alternator conforming to rdso drg. no. rdso/pe/sk/tl/0085-201 4 (rev 1) and material confirming to specn no. rdso/pe/spec/ac/0006 2009 (rev.1). however, the firms may quote for latest specification/ drawing with amendment if any issued by rdso/icf/rcf [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :40997527 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For supply of nylon 66 bush for suspension of 4.5 kw brushless alternator conforming to rdso specificatio n no. rdso/ pe. 0006.99 (rev - 0) and rdso drg. no. skel - 3942/ a alt - 1 to 4. [ warranty period: 30 m onths after the date of delivery ]

CTN :40287483 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For corrigendum : procurement of spares for plant 9 chillers. - 2893020013-drive shaft izl45x813lg part 11, 2893020023-sprocket wheel for gear cl 344, 2893020033-bearing neck ci188x221ig part 27, 2893020043-shear pin b16/12x60 do=5,5 part 16, 2893020053-set tpapered roller bearing (2 pcs ea), 2893020063-feltring 50 and (4pcs)feltstripe 9x7,5x3, 2893020073-follower/ conductor part 20,, 2893020083-chain 2" x10.000 mm part 154, 2893020093-cover b162x3 part 32

Central Government/Public Sector

CTN :40945885 Due date: 09 Jul, 202509 Jul, 2025 NA
Tender For supply of tensioning device assembly for 4.5 kw transom mounted brushless alternator to rdso drg.no. rdso / elec / skel / 3940 shee t-i alt.5 and sheet ii alt.5 or latest [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up